We thinks what clients think, the urgency of urgency to act from the interests of a purchaser position of principle, allowing for greater top quality, decrease processing costs, price ranges are much more reasonable, won the new and aged prospects the support and affirmation for Dengue Nsi Antigen Positive, nsi test for dengue, Rapid Test Human Coronavirus, We have been sincerely looking forward to developing very good cooperative relationships with buyers from at home and abroad for creating a vibrant foreseeable future together.
2020 Good Quality Novel Coronavirus (2019-Ncov) - COVID-19 IgG/IgM Rapid Test Cassette (Colloidal gold) – HEO Detail:

/products/

COVID-19 IgG/IgM Rapid Test Cassette (Colloidal Gold)

Accurate, effective, commonly used.

1
1
1
1

1.[1INTENDED USE]

The COVID-19 Antigen Rapid Test Cassette is a lateral flow immunoassay intended for the qualitative detection SARS-CoV-2 nucleocapsid antigens in nasopharyngeal swab and oropharyngeal swab from individuals who are suspected of COVID-19 by their healthcare provider.

2. [STORAGE AND STABILITY]

Store as packaged in the sealed pouch at temperature (4-30℃ or 40-86℉). The kit is stable within the expiration date printed on the labeling.
Once open the pouch, the test should be used within one hour. Prolonged exposure to hot and humid environment will cause product deterioration.
he LOT and the expiration date were printed on the labeling.

3. Sample Collection

Nasopharyngeal Swab Sample

Insert minitip swab with a flexible shaft (wire or plastic) through the nostril parallel to the palate (not upwards) until resistance is encountered or the distance is equivalent to that from the ear to the nostril of the patient, indicating contact with the nasopharynx. Swab should reach depth equal to distance from nostrils to outer opening of the ear. Gently rub and roll the swab. Leave swab in place for several seconds to absorb secretions. Slowly remove swab while rotating it. Specimens can be collected from both sides using the same swab, but it is not necessary to collect specimens from both sides if the minitip is saturated with fluid from the first collection. If a deviated septum or blockage creates difficulty in obtaining the specimen from one nostril, use the same swab to obtain the specimen from the other nostril.

1

Oropharyngeal Swab Sample

Insert swab into the posterior pharynx and tonsillar areas. Rub swab over both tonsillar pillars and posterior oropharynx and avoid touching the tongue, teeth, and gums.

1

Sample Preparation

After Swab specimens were collected, swab can be stored in extraction reagent provided with the kit. Also can be stored by immersing the swab head in a tube containing 2 to 3 mL of virus preservation solution (or isotonic saline solution, tissue culture solution, or phosphate buffer).

[SPECIMEN PREPARATION]

1.Unscrew the lid of an extraction reagent. Add all of the specimen extraction reagent into an extraction tube, and put it on the work station.

2.Insert the swab sample into the extraction tube which contains extraction reagent. Roll the swab at least 5 times while pressing the head against the bottom and side of the extraction tube. Leave the swab in the extraction tube for one minute.

3.Remove the swab while squeezing the sides of the tube to extract the liquid from the swab. The extracted solution will be used as test specimen.

4.Insert a dropper tip into the extraction tube tightly.

1

(The picture is for references only, please refer to the material object.)

[TEST PROCEDURE]

1.Allow the test device and specimens to equilibrate to temperature (15-30℃ or 59-86℉) prior to testing.

2.Remove the test cassette from the sealed pouch.

3.Reverse the specimen extraction tube, holding the specimen extraction tube upright, transfer 3 drops (approximately 100μL) to the specimen well(S) of the test cassette, then start the timer. See illustration below.

4.Wait for colored lines to appear. Interpret the test results at 15 minutes. Do not read results after 20 minutes.

5617

[INTERPRETATION OF RESULTS]

Positive:*Two lines appear. One colored line should be in the control region (C), and another apparent colored line adjacent should be in the test region (T). Positive for the presence of SARS-CoV-2 nucleocapsid antigen. Positive results indicate the presence of viral antigens but clinical correlation with patient history and other diagnostic information is necessary to determine infection status Positive results do not rule out bacterial infection or co-infection with other viruses. The agent detected may not be the definite cause of disease.

Negative: One colored line appears in the control region (C). No line appears in the test region (T). Negative results are presumptive. Negative test results do not preclude infection and should not be used as the sole basis for treatment or other patient management decisions, including infection control decisions, particularly in the presence of clinical signs and symptoms consistent with COVID-19, or in those who have been in contact with the virus. It is recommended that these results be confirmed by a molecular testing method, if necessary, for patient management.

Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test cassette. If the problem persists, discontinue using the lot immediately and contact your local distributor.


Product detail pictures:

2020 Good Quality Novel Coronavirus (2019-Ncov) - COVID-19 IgG/IgM Rapid Test Cassette (Colloidal gold) – HEO detail pictures

2020 Good Quality Novel Coronavirus (2019-Ncov) - COVID-19 IgG/IgM Rapid Test Cassette (Colloidal gold) – HEO detail pictures

2020 Good Quality Novel Coronavirus (2019-Ncov) - COVID-19 IgG/IgM Rapid Test Cassette (Colloidal gold) – HEO detail pictures

2020 Good Quality Novel Coronavirus (2019-Ncov) - COVID-19 IgG/IgM Rapid Test Cassette (Colloidal gold) – HEO detail pictures


Related Product Guide:

"Quality to start with, Honesty as base, Sincere company and mutual profit" is our idea, as a way to build constantly and pursue the excellence for 2020 Good Quality Novel Coronavirus (2019-Ncov) - COVID-19 IgG/IgM Rapid Test Cassette (Colloidal gold) – HEO , The product will supply to all over the world, such as: Israel, Thailand, Munich, Our company has built stable business relationships with many well-known domestic companies as well as oversea customers. With the goal of providing high quality products to customers at low cots, we've been committed to improving its capacities in research, development, manufacturing and management. We have honored to receive recognition from our customers. Till now we have now passed ISO9001 in 2005 and ISO/TS16949 in 2008. Enterprises of "quality of survival, the credibility of development" for the purpose, sincerely welcome domestic and foreign businessmen to visit to discuss cooperation.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Dawn from Guatemala - 2017.03.28 12:22
    This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Freda from America - 2018.12.11 11:26
    Write your message here and send it to us